Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Brand Name : | YOUCii |
Model Number : | U9225C |
Price : | Negotiate price |
Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability : | 10pcs / month |
Delivery Time : | 20 work days |
Four-Channel 24.5~29Gb/S Tunable Error Meter High Performance Test Equipment
The four-channel 24.5~29Gb/s tunable bit error meter is a kind of high performance test equipment, which is mainly used for the bit error rate test of high-speed digital communication systems and optical communication devices.
Product overview
The four-channel 24.5~29Gb/s tunable error meter integrates
functions such as internal reference clock, graphic signal
generator, clock recovery circuit and error analysis in one, which
can provide high-precision error rate testing. The device supports
four independent photoelectric channels, each with a rate of up to
29Gb/s, and is suitable for measurement of multiple rate devices.
The U9225C four-channel 24.5 ~ 29Gps tunable bit error meter is
mainly used for the bit error test of 100G TOSA/ROSA devices, and
can be easily used for the measurement of different speed devices.
The U9225C has the characteristics of high precision, high cost
performance, simple and convenient operation, etc., and has been
widely used in optical communication manufacturing production
lines, universities and scientific research institutions.
The U9225C integrates internal reference clock, graphic signal
generator, clock recovery circuit and error analysis in one, while
providing photoelectric interface and USB data communication
interface, each channel rate up to 29Gbps.
Product characteristics
High precision: The equipment adopts advanced testing technology
and algorithm, which can accurately measure the bit error rate of
the tested system to ensure the reliability of the test results.
High cost performance: Compared with similar products, the
equipment has a high cost performance and can meet the needs of
different users.
Easy to operate: The equipment is designed with a friendly user
interface and easy to operate control system, and users can easily
complete the test operation.
Versatility: In addition to the basic bit error rate test function,
the device also supports multiple test modes and custom test
sequences to meet different test needs.
Specification
Absolute Maximum Ratings | Symbol | Min. | Typ. | Max. | Unit | Notes |
Storage Temperature | Ts | -20 | – | 70 | °C | |
AC Voltage Range | VAC | 90 | – | 246 | VAC | |
AC Voltage Frequency Range | VFREQ | 47 | – | 63 | Hz | |
Data RF Voltage Input | VinData | -0.3 | – | 1.2 | V | |
Clock In Voltage Input | VinClk | 0 | – | 1.2 | V | |
USB Pin Voltage | VinUSB | -0.3 | – | 5.5 | V | |
RF and Clock ESD HBM | RFesdH | -1000 | – | 1000 | V | |
RF, Clock and USB Latchup | Vl | -100 | – | 100 | mA | |
USB ESD HBM | USBesdH | -2000 | – | 2000 | V | |
USB ESD CDM | USBesdC | -500 | – | 500 | V | |
Electrical Characteristics | Symbol | Min. | Typ. | Max. | Unit | Notes |
Case Temperature | Tc | 5 | – | 45 | °C | |
AC Supply Current | Icc | 0.75 | 200 | – | mA | |
Baud Rate (NRZ format) | BR | 12.25/24.5 | 14.5/29 | Gb/s | ||
Baud Rate Setpoint Accuracy | BRa | -10 | – | 10 | PPM | (Note 1) |
Baud Rate PPM Offset | BRo | -999 | – | 999 | PPM | 1 PPM step size |
Power On Initialization Time | Ton | – | – | 15 | Seconds | |
Eye Phase Steps | EMp | – | – | 128 | Steps | .16 pS per unit |
Eye Amplitude Steps | EMv | – | – | 64 | Steps | 8 mV per unit |
Note 1: Aging, Temperature and Voltage |
Scope of application
Four-channel 24.5~29Gb/s tunable error meter is widely used in the
following fields:
Optical communication manufacturing: In the development and production of optical communication devices (such as TOSA, ROSA, etc.), the equipment can be used to test the bit error rate performance of the device.
Universities and scientific research institutions: In scientific
research projects in the fields of optics and electronic
engineering, the equipment can be used to verify theoretical models
and test new technologies.
Digital communication system: During the installation, debugging
and maintenance of the digital communication system, the equipment
can be used to test the bit error rate performance of the system to
ensure the stable operation of the system.
![]() |