Optical Power Meter Small Module Can Be Used Independently With Built-In Chassis
The single channel optical power meter module converts the received optical signal into an electrical signal through the photoelectric effect, and then measures and displays the power of the optical signal. It is mainly used in optical fiber communication, optoelectronics, optical measurement and other fields to accurately measure and monitor the power of the light source.
Working principle
The working principle of single-channel optical power meter module
is based on the detection and processing of photoelectric effect
and electrical signal. Specifically, when light strikes a
photosensitive element (such as a photodiode), the energy of the
photon is converted into the kinetic energy of the electron, which
creates a current or voltage in the photosensitive element. This
weak electrical signal is then amplified, filtered,
analog-to-digital conversion and other processing steps, and
finally converted into a digital signal and displayed on the
display screen of the instrument or presented to the user through
the computer interface.
Main feature
High-precision measurement: Single-channel optical power meter
modules usually have high-precision power measurement capabilities
to ensure accurate measurement results even at low power
conditions.
Wide wavelength range: In order to accommodate the operating
wavelengths of different lasers, the single-channel optical power
meter module needs to cover a wide wavelength range.
Fast response: Some applications need to measure rapidly changing
optical power, so the single-channel optical power meter module
needs to have fast response characteristics.
Environmental adaptability: Optical power meters are often used in
various environments, such as laboratories, industrial production
lines, etc., so single-channel optical power meter modules need to
have good environmental adaptability.
Specification
Model | U8201MINI |
Sensor Element | InGaAs |
Wavelength Range | 850 ~ 1700 nm |
Calibration wavelength | 850/980/1310/1490/1550/1610 nm |
Power Range (dBm) | +7 ~ -70 dBm |
Power sampling period(Rate) | 1 ms(1KHz) |
Application Fiber Type | Standard SM and MM up to 62.5 um core size |
optical Input Interface | FC/PC or FC/APC |
Absolute Uncertainty (accuracy) at reference condition | ± 4% (1200 nm ~ 1610 nm) |
Relative Uncertainty (accuracy) at reference condition | < 0.02 dB Typical |
Linearity (power) | ≤ ± 0.06 dB (1200 nm ~ 1610 nm, 5~ -50dBm) |
Return Loss | > 40 dB |
Communication Interface | RS232 |
Calibration period | 2 years |
Operation Temperature | 0 ~ +40℃ |
Storage Temperature | -30 ~ +80℃ |
Dimensions | 37 mm W, 25 mm H, 115 mm D |
Weight | 0.2 kg |
Application scenario
Single-channel optical power meter module is widely used in the
following scenarios:
Test and maintenance of optical fiber communication systems.
Power measurement in the development and production of
optoelectronic devices.
Power monitoring in optical experiments and research.
![]() |